• home
  • portfolio
  • what's new
  • Batesville Net-Zero Residence
  • contact
  • german
Menu

bg design & consulting :: architectural design for better living and a better world

  • home
  • portfolio
  • what's new
  • Batesville Net-Zero Residence
  • contact
  • german

breaking news:

what's new
bg design & consulting and Liminal Architecture join forces
about 7 years ago
Mourning Prof. Manfred Hegger, pioneer of sustainable, energy-efficient architecture
about 8 years ago
Habitat for Humanity Washington D.C. Ivy City Passive Houses earns Passive House certification
about 9 years ago
Winning 1st place in 'best under 35' Passive House Building Award for ecoMOD South
about 9 years ago
Habitat D.C. Ivy City Passive Houses to be toured by PHIUS Builder Training and Passive House Alliance Meeting
about 11 years ago
2013 North American Passive House Conference in Pittsburgh
2013 North American Passive House Conference in Pittsburgh
about 11 years ago

connect with bg:

HERE you can link up with us on Facebook to stay connected. 


P8230061.JPG P8230056.JPG P8230181.JPG P8230181.JPG

What makes the Batesville residence 'net-zero' or 'energy-positive'?

August 31, 2016

Passive measures

  • a well-insulated, airtight but vapor-open building-envelope to minimize energy-losses (R28 above ground walls, R24 basement walls, R26 slabs, R54 roofs, windows and doors with R11 triple-pane glazing and R7 wood-clad frames, Airtightness 0.34ACH @50Pa)
  • generous overhangs for shading to prevent over-heating but allow solar gains in the winter
  • exposed concrete floors, insulated from below, to provide thermal mass to help the house stay comfortable by equalizing temperature swings
  • window and door openings are designed to allow for solar gains in the winter from morning and mid-day sun, minimize energy losses by being less in number or smaller on the north side, support cross-ventilation and natural cooling, and also allow for generous daylight, framingviews and providing generous indoor-outdoor connections in all directions

 

Active features

  • the space conditioning system is comprised of two 1t ducted mini-split heat-pumps with variable speed compressors (a similarly sized to-code-home would need 4-6t of air-conditioning capacity), an ERV to provide continuous fresh-air ventilation, while preserving and transferring the energy of the conditioned exhaust-air to the incoming fresh-air
  • a wood-burning stove with direct air supply and a sealed combustion chamber serves as back-up and atmospheric heat source on cold days
  • hot water is generated by an electric heat-pump hot-water-heater that uses room temperature air to generate heat for domestic hot water, simultaneously dehumidifying the air in the basement
  • LED lighting throughout
  • energy-efficient appliances such as an induction cooktop and an electric heat-pump dryer
  • the electric consumption is estimated to be 7,000-10,000 kWh/year
  • a 7.2kWp photovoltaic array adjacent to the house is calculated to generate 10,000 kWh per year of solar energy. It will feed the grid with excess energy on sunny days, while the house will draw from the grid at night or on cloudy days. 
  • the installed inverter already allows to plug-in vital appliances during a power outage. Upon market availability the owners plan to install a lithium-ion battery bank allowing the pv system to supply the house for several days.
Batesville House achieves 0.34 ACH50 in first Blower Door Test →